Slitting line manufacturer from China

Top cut to length production line producing company: The consequences of poor power quality, including voltage unbalances, can be far-reaching: Random Equipment Malfunctions: Voltage sags, swells, transients, and harmonics can cause unpredictable equipment malfunctions, leading to unscheduled downtime, reduced productivity, and increased maintenance costs. Data Corruption: Poor power quality can cause errors in data processing equipment, leading to data corruption and loss of valuable information. Loss of Process Control: Voltage unbalances and other power quality issues can disrupt process control systems, affecting the quality of the output and leading to production losses. Regular monitoring is indispensable in identifying and addressing power quality issues promptly. Implementing effective strategies to manage these issues can significantly mitigate their adverse impacts. These might include investing in innovative solutions like those offered by companies such as CANWIN Automatic Equipment Co., Ltd. With their commitment to quality and innovation, such businesses play a crucial role in helping others maintain high power quality and, in turn, achieve optimal performance and longevity of their transformer equipment. Find even more info on cut to length production line.

What are the consequences of parallel operation of transformers that do not meet the parallel operation conditions? Parallel operation of transformers that do not meet the parallel operation conditions may lead to the following consequences: Voltage instability: Different transformers may have different electrical parameters, such as transformation ratio, resistance, inductance, etc. If these transformers with different parameters are forced to run in parallel, the overall electrical parameters after paralleling may be unstable, thereby affecting the quality of power supply. Uneven load distribution: If the transformers with uneven load distribution are forced to run in parallel, different transformers may bear different loads, thus affecting the service life and stability of the transformers. Excessive temperature rise: If different transformers are operated in parallel, their heat dissipation conditions and methods may be different, which may cause excessive temperature rise of some transformers, and may even damage the transformer.

The efficiency of the transformer refers to the energy conversion efficiency of the transformer, that is, the ratio of the output power to the input power. Improving the performance of transformers can reduce energy loss and energy consumption, thereby improving the economy and reliability of transformers. Here are a few ways to improve transformer performance: Optimizing transformer design: When designing a transformer, optimized design methods can be used, such as reducing the reluctance of the iron core and winding, reducing copper loss and iron loss, etc., thereby reducing the energy loss of the transformer and improving performance. Choose high-quality materials: When manufacturing transformers, you can choose high-quality materials, such as low-loss silicon steel sheets, high-conductivity materials, etc., to reduce material loss and energy consumption and improve performance.

The company mainly produces 150 model oil-type transformercore shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage transformer tc. CANWIN hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.

The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.

The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.

Box transformer (usually referred to as “box transformer”) is a compact complete set of power distribution equipment composed of high-voltage power equipment, power transformer, low-voltage electrical equipment and auxiliary equipment. Canwin, a professional box transformer manufacturer & supplier, which focuses on the substation type transformer and traditional box type transformer design in the box shell, A box type transformer is an electronic device that transforms power into alternating current for the purpose of transferring power from one point to another.With small volume, light weight, low noise, low loss, high reliability. Transformer box is widely used in residential areas, commercial centers, light stations, airports, factories and mines, enterprises, hospitals, schools and other places.

The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. Find more info on canwindg.com

Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.

With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.

Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.